Hard disk drives / solid state drives
7.3.4
Replacing a 3.5-inch HDD module
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD module during operation if the drive is not
●
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "PRIMERGY CX400 S1 Server
Enclosure Operating manual".
Under no circumstances should you remove an HDD module while
●
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
●
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
7.3.4.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps: tool-less
●
7.3.4.2
Preliminary steps
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
or from the ServerView Suite DVD 2 supplied with your PRIMERGY
server.
118
Upgrade and Maintenance Manual
http://manuals.ts.fujitsu.com
CX400 S1