COM2
124
SD Series Ref. Manual (Packet & Transparent Mode)
—eight char bits, no parity, one stop bit (default setting)
8N1
—eight char bits, no parity, two stop bits
8N2
—eight char bits, odd parity, one stop bit
8O1
—eight char bits, odd parity, two stop bits
8O2
—eight char bits, even parity, one stop bit
8E1
—eight char bits, even parity, two stop bits
8E2
NOTE: Entering data formats other than those listed above may cause
undesired operation.
Sets or displays the
COM2
Optional arguments:
=<choices>—Serial port mode.
MODE
COM2
RS232
COM2
RS485
—Sets or displays baud rate setting as 1200, 2400, 4800,
BAUD=<bps>
9600, 19200, 38400, 57600, or 115200 bps.
—Sets or displays the
FORMAT=<format>
parity, and stop bits setting. Valid data parameters are:
—seven char bits, no parity, one stop bit
7N1
—seven char bits, no parity, two stop bits
7N2
—seven char bits, odd parity, one stop bit
7O1
— seven char bits, odd parity, two stop bits
7O2
—seven char bits, even parity, one stop bit
7E1
—seven char bits, even parity, two stop bits
7E2
—eight char bits, no parity, one stop bit (default setting)
8N1
—eight char bits, no parity, two stop bits
8N2
—eight char bits, odd parity, one stop bit
8O1
—eight char bits, odd parity, two stop bits
8O1
—eight char bits, even parity, one stop bit
8E1
—eight char bits, even parity, two stop bits
8E2
NOTE: Entering data formats other than those listed above may cause
undesired operation.
—Sets or displays the buffer status on
BUFF=<on/off>
—Data handling off
OFF
—Data handling on
ON
The
command controls or displays the device behavior of the
DEVICE
radio. The command parameter is either
port configuration.
defaults to RS-232 operation
defaults to RS-485 operation
COM2
DCE
port data characters,
:
COM2
.
MDS 05-4846A01, Rev. C