6-3. Group Sequence
A Group Sequence consists of up to 64 steps.
In each step a maximum of 16 cameras can be assigned to 16 monitors.
Pan/Tilt preset and AUX control 1 & 2 can also be set for each camera/monitor combination.
Camera switching (Dwell Time) for each step can be set from 1 sec. to 30 sec. with 1 sec. increments.
There are 8 Group Sequences available, with programming performed in the Set Up Menu.
C 13
C 14
C 9
C 10
C 5
C 6
C 1
C 2
Group Sequence
7. Timer
The timer function is used to program and automatically activate tour or group sequences from set start times to set stop times
during each day of the week and 5 user defined special days.
8. Alarm
8-1. Alarm Input
1. Camera Site Alarm
This alarm signal is supplied from the associated camera site receiver.
The applicable units for camera site alarm inputs are the WV-RC100, WV-RC150 and WV-RC170 Receivers.
2. Interface Alarm
This alarm signal is supplied from the Alarm Input Connector on the optional Alarm Board installed in the WJ-SX550A Matrix
Switcher.
Up to 128 alarm inputs are available.
8-2. Alarm Operation Mode
There are three alarm operation modes available in the WJ-SX550A Matrix Switcher.
The alarm modes are able to switch according to the time programmed in an internal timer.
4th Floor
C 15
C 16
3rd Floor
C 11
C 12
2nd Floor
C 7
C 8
1st Floor
C 3
C 4
CAM 13
CAM 14
CAM 15
CAM 9
CAM 10
CAM 11
CAM 5
CAM 6
CAM 7
CAM 1
CAM 2
CAM 3
Monitor 1
Monitor 2
Monitor 3
-17-
CAM 16
CAM 12
CAM 8
CAM 4
Monitor 4
2

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Wj-cu550a

Table of Contents