3-10 Basic Console Operations

3-10-12 To Set Up a De-Esser Using Dynamics Side-Chain EQ

1
1
Press {ACCESS} for the desired Channel.
2
At the Input Channel & Inserts panel, select
'DYN' in one of the eight windows. Do this using
the { + } and { – } buttons, and then press the large
{ IN } button.
3
At the Free Assign Area & Dynamics panel, select
SC EQ IN; its {ACCESS} button will light
automatically.
4
At the same panel, press the button adjacent to the
SIG EQ display and adjust the HF controls to
boost the frequency band to be attenuated.
3-30
Chapter 3 Getting Started
6
3
5
4
7
2
5
Now de-select SIG EQ and select S-C EQ to
affect just the side-chain signal.
6
At the same panel, select COMPRESS { IN } . The
Compressor {ACCESS} will be selected
automatically, allowing the compressor to be set.
7
Select the Dynamics softkey to view compressor
parameters and transfer curve graph on the LCD
screen.