4 SOLO + CHs UNDER Push-Button
Sets a Solo mode where channels which are not soloed can be heard at a
reduced level. The level is set using the Definable knob above the Monitor
Level control. Use the { + } and { – } buttons either side of the 8 character
display above the Definable knob to select DIM LEVEL, and adjust to
suitable level.
5 SOLO ISOL Push-Button
To isolate channels from the solo-cut bus, latch SOLO ISOL and select
their channel SOLO buttons. Then de-latch SOLO ISOL. Reverse the
procedure to de-isolate channels. Latching SOLO ISOL will cause the
SOLO buttons on isolated channels to light.
6 AUTO CUE Push-Button
Latching function linked to T/B GROUP 2 push-button. When AUTO
CUE is selected, T/B GROUP 2 will be permanently latched on apart from
when the tape is rolling. This enables talkback at all times except when
the tape is playing or recording. Talkback buttons (e.g. T/B F/Back 1-4)
must be assigned to T/B GROUP 2 for this function.
Buttons related to Copy
The following descriptions relate to Copy functions which are carried out
using the Channel {ACCESS} buttons decribed in detail in Chapter 7. Here
is a brief description of copying and/or linking the settings of one channel
to others:
COPY
• Press and hold upper {ACCESS} button of source channel until it turns
amber.
• Press and release upper {ACCESS} buttons on destination channels.
LINK
• Press and hold lower {ACCESS} button of source channel until it turns
amber.
• Press and release lower {ACCESS} buttons on destination channels.
COPY & LINK
• Press and hold lower {ACCESS} button of source channel until it turns
amber.
• Press and release upper {ACCESS} buttons on destination channels.
7 COPY DYN Push-Button
This is a latching function and applies to to all 'COPY' and 'QUICK
COPY' functions, which are performed using button push operations
(these are described in Chapter 7). If {COPY DYN} is selected, any copy
operations will include dynamic automation data. {COPY DYN} inter-
cancels with {COPY STATIC} 8, or it an be turned on and off, when it
returns to defaults.
8 COPY STATIC Push-Button
This is a latching function and applies to to all 'COPY' and 'QUICK
COPY' functions, which are performed using button push operations
(these are described in Chapter 7). If {COPY STATIC} is selected, any