Installation and mounting
5.5 Setting up the charging station
5.5.6

Mounting the roof and filter cover

This section describes the installation of the roof and the filter cover. If no cable management
system is installed, then skip the section.
Figure 5-25  Mounting the roof and filter cover
1. Loosen the four quarter-turn fasteners of the filter box and remove it.
2. Slide the roof from the back of the charging station forward under the metal guides
provided.
3. Screw down the roof at the bottom left and right with two M6 combination screws from
the box of accessories.
4. Insert the filter box and secure it with the four quarter-turn fasteners.
5. Place the filter cover from the box of accessories onto the roof. Attach the grounding
cable to the threaded bolt in the filter cover with the tightening torque of 4 Nm.
6. Remove the rear device door. Note the information on the locking system from the section
"Overview (Page 33)".
7. Click the filter cover first upwards and then downwards in the cabinet. Lock the quick
fasteners and install the rear device door again.