If the charging station is configured and prepared for a dispenser, then the charging station
automatically has the High Flex variant. If you don't want to connect a dispenser, you can
select between the two variants. The figure below shows this connection.
Figure 3-12 Low Flex and High Flex variants
The following table shows the available output power per DC output for the High Flex variant.
Table 3-9 High Flex variant
Number
of
vehicles
160 kW
180 kW
200 kW
* = via dispenser
SICHARGE D
Operating Instructions, 11/2023, A5E50556539-AG
1
2
DC 1
DC 2
160
120
40
80
80
40
120
180
120
60
80
100
40
140
200
140
60
100
100
3*
DC 1
DC 2
DC 3
40
40
80
40
80
40
80
40
40
40
60
80
40
100
40
80
60
40
40
60
100
40
100
60
Description
3.8 Dynamic power distribution
4*
DC 1
DC 2
DC 3
40
40
40
40
60
40
40
60
60
DC 4
40
40
40
47