Siemens SICHARGE D Operating Instructions Manual page 74

Hide thumbs Also See for SICHARGE D:
Table of Contents

Advertisement

Installation and mounting
5.2 Installation location
Shading
Choose the location of the charging station so that the device is protected from direct
sunlight. If necessary, install suitable shading equipment as shown in the following example
figure. Direct sunlight can additionally heat the charging station and charging cables. If the
charging station gets too warm, the charging power is reduced (derating) or the charging
station switches off.
Strong UV radiation can cause premature aging of the insulation of the charging cables. This
could significantly reduce maintenance intervals.
Figure 5-2  Example of shading
Maximum operating temperature at the air inlet
The maximum operating temperature at the air inlet is 55 °C. In the range between 35 °C and
55 °C, the available charging power may be reduced depending on the duration of the
charging process and the requested power of the vehicle (derating).
Direction of air flow
The supply air enters the two sides and the back of the charging station from below. The
airflow inside the charging station is from the bottom to the top. The warm exhaust air
escapes on both sides and the back. This means that the warm exhaust air does not reach the
operator at the front of the charging station.
The operator must ensure that the air entry openings are kept free and not blocked by
obstacles, such as snow or leaves.
74
Operating Instructions, 11/2023, A5E50556539-AG
SICHARGE D

Advertisement

Table of Contents
loading

This manual is also suitable for:

8em5907-0aa00-1aa7.06