Commissioning

7.3 Setting the thermostat

Automatic startup
The SICHARGE UC Dispenser starts automatically. Wait until the SICHARGE UC Dispenser has
started up completely. When the display shows the Start menu, the SICHARGE UC Dispenser is
ready for operation.
Figure 7-1  Start menu
7.3
Setting the thermostat
Set the thermostat in the dispenser correctly to prevent condensation.
Thermostat setting table
The thermostat setting depends on the humidity conditions and temperature conditions
prevailing at the particular location of the Dispensers. The following table is based on
EN ISO 8502-4. The table indicates the temperature setting on the thermostat depending on
the ambient temperature and relative humidity.
Table 7-1  Thermostat setting table
Average ambient air
temperature
5 °C
10 °C
15 °C
20 °C
25 °C
66
20 %
35 %
0 °C
0 °C
0 °C
0 °C
0 °C
0 °C
0 °C
5 °C
1 °C
9 °C
Average relative humidity
50 %
65 %
0 °C
0 °C
1 °C
4 °C
5 °C
9 °C
10 °C
14 °C
14 °C
18 °C
Operating Instructions, 06/2023, A5E50235695-AE
80 %
95 %
2 °C
5 °C
7 °C
10 °C
12 °C
15 °C
17 °C
20 °C
22 °C
25 °C