Topic = Voting; Topic = Voting, Data-Item = Num; Topic = Voting, Data-Item = Name; Topic = Voting, Data-Item = Subject - Bosch DCN Manual

Table of Contents

Advertisement

External Interface Manual
Layout
"delegate ID, authorization, delegate ID, authorization, ..."
where:
delegate ID
authorization
Delegate ID and authorization are separated by commas. This sequence is repeated for each delegate, again
separated by commas.
Examples
1,5,2,2
In this example delegate 1 has microphone and intercom authorization. Delegate 2 only has voting
authorization.
Requirements
This link is always available. If there is a names file the string as described above is sent whenever a change
in the delegate database occurs. If there is no names file or the names file is empty an empty update is sent.
2.2.2

Topic = VOTING

2.2.2.1.

Topic = VOTING, data-item = NUM

Purpose
Supplies the number of the current vote.
Layout
A decimal number in the range 1-9999.
Requirements
At least one of the voting applications is running and the Hall Display setting in the voting application is set to
"On".
2.2.2.2.

Topic = VOTING, data-item = NAME

Purpose
Supplies the name of the current vote.
Layout
A string of at most 20 characters.
Requirements
At least one of the voting applications is running and the Hall Display setting in the voting application is set to
"On".
2.2.2.3.

Topic = VOTING, data-item = SUBJECT

Purpose
Supplies the motion subject text of the current vote.
Layout
A string of at most 132 characters containing the 4 lines of the subject text, without separators between them.
(If there are commas in the string they are part of the subject text.)
Requirements
At least one of the voting applications is running and the Hall Display setting in the voting application is set to
"On".
2.2.2.4.

Topic = VOTING, data-item = KIND

Purpose
Supplies the type of the current vote.
Layout
A string containing one of the following texts (or their translations if DCN is installed in another language):
"Parliamentary"
"For/Against"
"Audience Response"
Bosch Security Systems B.V. | 2004 April | External Interface Manual
A number in the range 1-1000 (single CCU) or 1-1500 (multi-
CCU) that identifies the delegate in the delegate database.
Each delegate has a unique ID-number.
a number that represents the authorizations the delegate has. It
will be the sum of 1 or more of the following numbers:
0
for no authorization
1
for microphone authorization
2
for voting authorization
4
for intercom authorization
en | 9

Advertisement

Table of Contents
loading

Table of Contents