Panasonic DBS Series Programming Manual page 19

Digital business system
Hide thumbs Also See for DBS Series:
Table of Contents

Advertisement

Panasonic Digital Business System - Programming Manual
April 1997
Digits of extension number
[CONF]: 3-digit extension number
(2-4)#: 2-digit extension number ~ 4-digit extension number
This step sets the size of extension numbers to 2,3 or 4 digits. The maximum ranges are shown
below. This setting applies system wide and is automatically set to 4 digits when E&M Private
Circuits are installed.
Extension number ranges are:
2 digits
3 digits
4 digits
E&M Used
Note: When this step is changed a soft reset must be performed by switching the system off and
back on
Related step
FF3 (001 - 144)# 1# - Extension Number
FF1-2#-1#-28#
[NOT USED]
FF1-2#-1#-29#
[NOT USED]
Un-answered DISA call transfer to operator
0#: Transfer to the extensions which are assigned to ring.
1#: Transfer to an operator telephone.
If a DISA incoming call is not answered within the specified time, the call can be transferred to an
operator telephone or the extensions which are assigned to ring where it will appear as a normal
incoming call.
Related step
FF1 3# 27# - DISA No Answer Timer
# key feature in DISA call
0#: To terminate a DISA call
1#: To change to a normal incoming call
This specifies how the system will handle the # character when it is received from a DISA call
before it has connected to an extension. If it is set to become a normal call it will ring as per un-
answered DISA transfer to operator.
Related step
FF1 2# 1# 30# - Un-answered DISA call transfer to operator
FF1-2#-1#-27#-(2-4)#
20 ~ 59
(40 extensions maximum on the system)
200 ~ 599
2000 ~ 5999
2200 ~ 2599,3200 ~ 3599,4200 ~ 4599 or 5200 ~ 5599
FF1-2#-1#-30#-(0-1)#
FF1-2#-1#-31#-(0-1)#
19
[INT CALL DIGIT]
(P)
[DISA ATT TRANSF]
[DISA DIAL '#']
Issue 15
2.x
2.x
3.1

Advertisement

Table of Contents
loading

Table of Contents