Bosch Rexroth SMART Flex Effector Manual page 79

Table of Contents

Advertisement

79
You can now take measures to rectify the error, depending on the possible error sources:
Error source
Error pattern
Internal
Error in
electronics
communication
with the
EEPROM, with
position sensors,
with the
temperature
sensors or with
the interprocessor
communication
RS485
Communication
with the RS485
interface not
possible /
defective
Error when
Motor
installing / moving
with the motor
24
Rectification measures
en
Possible cause
EEPROM defective,
position sensor defective,
temperature sensor
defective, F100 MCR
defective, cold solder joint,
loose contact,
electromagnetic
interference
Unidirectional
communication protocol
(request/response) is not
adhered to, connection
line too long, defective
connection line,
electromagnetic
interference, RS485
transceiver or interface
defective, cold solder joint,
loose contact
Motor overload,
overcurrent shutdown, low
supply voltage, cable too
long, cable defective,
overload (weight), voltage
breakdown, short-circuit,
hardware defective,
position sensor defective,
magnet for position
determination too weak,
incorrect size of power
supply unit