Parameter Descriptions
DR-68 Freq. Input #33 [Hz]
Range:
0
[0 - 130000] View the actual value of the frequency applied
*
3
3
DR-69 Pulse Output #27 [Hz]
Range:
0
[0 - 40000] View the actual value of pulses applied to
*
DR-70 Pulse Output #29 [Hz]
Range:
0
[0 - 40000]
*
DR-71 Relay Output [bin]
Range:
0
[0 - 511]
*
DR-72 Counter A
Range:
0
[-2147483648
*
- 2147483647]
DR-73 Counter B
Range:
0
[-2147483648
*
- 2147483647]
132
Function:
at terminal 33 as an impulse input.
Function:
terminal 27 in digital output mode.
Function:
NOTICE
This parameter is available for AF-650 GP
only.
View the actual value of pulses at terminal 29 in
digital output mode.
Function:
View the settings of all relays.
Illustration 3.44 Relay Settings
Function:
View the present value of counter A.
Counters are useful as comparator operands,
see parameter LC-10 Comparator Operand.
Reset or change the value either via digital
inputs (parameter group E-0# Digital Inputs)
or by using an LC action
(parameter LC-52 Logic Controller Action).
Function:
View the present value of counter B.
Counters are useful as comparator operands
(parameter LC-10 Comparator Operand).
Reset or change the value either via digital
inputs (parameter group E-1# Digital Inputs)
or by using an Logic Controller action
(parameter LC-52 Logic Controller Action).
DR-74 Prec. Stop Counter
Range:
0
[0 - 2147483647] Returns the actual counter value of
*
DR-75 Analog In X30/11
Range:
0
[-20 - 20] View the actual value at input X30/11 of General
*
DR-76 Analog In X30/12
Range:
0
[-20 - 20] View the actual value at input X30/12 of General
*
DR-77 Analog Out X30/8 [mA]
Range:
0
[0 - 30]
*
3.18.6 DR-8# Fieldbus & Drive Port
Parameters to view the bus references and control words.
DR-80 Fieldbus CTW 1
Range:
0
[0 -
*
65535]
DR-82 Fieldbus REF 1
Range:
0
[-200 -
*
200]
DR-84 Comm. Option STW
Range:
0
[0 - 65535] View the extended fieldbus communication
*
DR-85 Drive Port CTW 1
Range:
0
[0 -
*
65535]
02/2016 All rights reserved.
Function:
precise counter (parameter H-84 Precise
Stop Counter Value).
Function:
Purpose I/O OPCGPIO.
Function:
Purpose I/O OPCGPIO.
Function:
View the actual value at input X30/8 .
Function:
View the 2-byte control word (CTW) received
from the fieldbus master. Interpretation of the
control word depends on the fieldbus option
installed and the control word profile selected in
parameter O-10 Control Word Profile.
For more information, refer to the relevant
fieldbus manual.
Function:
View the 2-byte word sent with the control
word from the fieldbus master to set the
reference value.
For more information, refer to the relevant
network manual.
Function:
option status word.
Function:
View the 2-byte control word (CTW) received
from the fieldbus master. Interpretation of the
control word depends on the fieldbus option
installed and the control word profile selected
in parameter O-10 Control Word Profile.