Connection
Supply line
U
V
PE
Supply line
U
(
V
(
PE
(
11--14
PSU 5000 / PSG 3000
Instructions for Assembly and Operation
Case 3
Transformer
(
MPE
(
(
Housing
Negative pole grounded via protective conductor jumper (MPE), workpiece
grounded, transformer housing has a low--resistance connection to
welding equipment (practical case).
There will be circulating currents through the mains supply line and further-
more through the welding equipment.
Case 4
Transformer
Rectifier
MPE
Housing
Negative pole grounded via protective conductor jumper (MPE), workpiece not
grounded, several electrode guns simultaneously weld the workpiece (whose neg-
ative pole is also grounded).
There will be circulating currents through the "neighboring" electrode
guns.
More circulating currents are present if the workpiece is additionally
grounded (cf. Case 3).
Rectifier
+
- -
+
Workpiece
- -
Workpiece
through the
MPE