Mechanical Data; Environmental Data - Bosch PSU 5000 Series Instructions For Assembly And Operation Manual

Mf welding inverters
Table of Contents

Advertisement

Technical
data

5.1.3 Mechanical data

(Air- -cooled)
W: 203 mm
Dimensions
H: 463 mm
D: 278 mm
Weight
approx. 19.3 kg

5.1.4 Environmental data

(Air- -cooled)
Location
Position
vertically; on rear wall
Ambient tem-
perature of
module
Storage tem-
perature
Protection class
Humidity class F to DIN 40040; 20ûC with 90% rel. humidity, 40ûC with 50% rel. humidity (to VDE 0113)
Humidity
Air pressure
Corrosion
the ambient air must be free from major concentrations of acids, caustic solutions, corrosive agents, salt and metal
Cooling
air
with Bosch fan cowl
max. 45 ûC
5--2
PSU 5000 / PSG 3000
Instructions for Assembly and Operation
PSU 5100
PSU 5300
(Water- -cooled)
approx. 17 kg (aluminum heat sink)
approx. 25 kg (brass heat sink)
PSU 5100
PSU 5300
(Water- -cooled)
Installation in switch cabinet with protection class IP54; note PSU power loss
0 ûC to +55 ûC; with prescribed cooling
- -25ûC to +70ûC; when water- -cooled: Heat sink must have been drained!
Condensation on the modules is not permitted.
in the range up to 2000 m above sea level.
water connection through M16x1.5 external thread with taper steps to DIN EN 560
W: 203 mm
H: 463 mm
D: 228 mm
vertically; installation on switch cabinet mounting plate
IP 20 to DIN 40050
vapors
water; 4 l per min.; max. 30û C; ∆p: max. 1 bar
PSU 5200
W: 250 mm
H: 653 mm
D: 280 mm
approx. 40 kg (aluminum heat sink)
approx. 55 kg (brass heat sink)
PSU 5200
1070 078 224- -108

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents