Ensuring Emc Of The Comprehensive System - Bosch PSU 5000 Series Instructions For Assembly And Operation Manual

Mf welding inverters
Table of Contents

Advertisement

Ensuring EMC of the comprehensive system

1070 078 224--- 109
PSU 5000 / PSG 3000
Instructions for Assembly and Operation Safety instructions
NOTE
The comprehensive system comprising PSU in connection with PSG complies with
prEN 50240, the EMC product standard for resistance welding systems, and
EN 55011 (October 1997), EMC product family standard class A, group 2, rated
current > 100 A.
-- only for industrial applications.
-- safe clearance to residential areas ≧ 30 m.
-- safe clearance to communication systems (wireless, telephone) ≧ 10 m.
-- cable length of mains feeder (PSU) ≧ 10 m.
-- interference suppression measures: When switch cabinet doors are open,
radio devices and cell phones may only be used in a safe clearance of ≧ 2 m.
The assessment and certificate of conformity of a competent authority concer-
ning compliance with the fundamental EMC protection is available.
When the MF components are integrated in a Schweisskoffer type GK 100 L MF00,
the Schweisskoffer is awarded the CE label in accordance with the EMC Directive
89/336/EEC. Additional EMC tests of the Schweisskoffer are not necessary.