5.3.4 PSU 5100.XXX / PSU 5300.XXX and PSG 3050.00 A

Limitation by transformer (and PSU)
Limitation by diodes with 50 cycles weld time
Limitation by diodes with 20 cycles weld time
Limitation by diodes with 10 cycles weld time
Limitation by diodes with 5 cycles weld time
1070 078 224- -108
PSU 5000 / PSG 3000
Instructions for Assembly and Operation
The power data for PSU 5100/PSU 5300 = 50 kW and PSU 5200 = 100 kW are
calculated from the respective continuous current (110 A and 220 A) and the 500 V
output voltage of the inverters.
PSU 5100 / PSU 5300: P ≈ 110 A x 500 V ≈ 50 kW
PSU 5200: P ≈ 220 A x 500 V ≈ 100 kW
The devices are rated for this load, i.e. the copper bars, connection terminals, elec-
trolyte capacitors are rated accordingly.
For comparing different inverters, it will not be sufficient to verify the peak current
(e.g. 20 kA); instead, the respective continuous loads have to be compared.
PSG integration time: 60s
ED (duty cycle) [%]
Diode integration time: 2 s
The load curves represent ab-
solute limit values. For a re-
liable continuous operation, we
recommend utilizing these limit
values by no more than 80%.
Technical
data
5--5