Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Undefined Messages
When a common format message contains unprintable hexadecimal characters (unprintable
characters are out of ASCII range 0x32-0x7E) or without an account block:
SIA Example
SIA Mode Description
<LF><CRC><TAB><sequence#><receiver#><line#>[data]<CR>
Table 57: Common Formats (Message Type <TAB>) Byte Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
Data
Figure 15: Message sent to printer
MM/DDsHH:MMsLxx[SIA]
+++ TEXT 1
+++ TEXT 2
54
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical Redundancy Check number.
09 hex.
The message sequence number. The valid sequence number range is
0001 to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The D6600/D6100/D6100IPv6 uses
Line 0 (zero) for receiver gateway messages.
The receiver message contains hex characters either with or without
account portion.