Bosch Conettix D6600 Manual page 137

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem
IIIa
.
ZONEX and Comex Translation
These items supply additional information related to Appendix C: Modem4/ModemIIIa
of these numbered items are also referenced in the Comments section of Appendix C.
1. When Point User Flag is programmed to Yes in panel programming of panels that support this
function, the zone and point information will be translated. The D6600/D6100 converts point data to
ZONEX format and user IDs to Comex format. Table 99 shows the translation of point data and Table
100 shows the translation of User IDs. If Point User Flag is programmed to a No in the panel, then
the zone and point information are sent as received.
Table 99: Point to ZONEX Translation
Point
001-008
009-024
025-040
041-056
057-072
073-088
089-104
105-120
121-136
137-152
153-168
169-184
185-200
201-216
217-232
233-247
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
ZONEX
100-800
101-116
201-216
301-316
401-416
501-516
601-616
701-716
801-816
117-132
217-232
317-332
417-432
517-532
617-632
717-731
2