Silent Knight Fsk1 (Message Type M) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols

3.1.24 Silent Knight FSK1 (Message Type m)

Silent Knight
D6500 Byte Description
FSK1 Example
1
2
h
m
Table 29: Silent Knight FSK1 (Message Type m) Byte Description
#
Title
1
Header
Character (h)
2
Message Type
3-4
Receiver
Number
5
Line/Group
Number
6
Spaces
7-14
Account
Number
15
"
16-19
EEZZ
20
"
21 - 28
***
28
Trailer
Character
32
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3
4
5
6
7
8
r
r
l
s
a
a
Description
Optional. Check with the computer automation software for
compatibility.
m
Receiver gateway number from 01 to 99.
Line number in the receiver gateway that sent the message.
One space.
Maximum 8-digit account code. If the account code is less than 8
digits, enter the actual number of digits without a leading space.
Separator.
First event and zone number. If this is the only event, it will be ended
with the terminator. Up to 8 reports. One report has 4 digits: 1-digit
event code, 1-digit condition code, 2-digit zone code.
Separator.
Next data.
Typically, HEX 14.
9
10 11 12 13 14 15 16 17 18 19
a
a
a
a
a
a
21-
28
"
E
E
Z
Z
...
29
t

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100ipv6Conettix d6100i