Bosch Conettix D6600 Manual page 176

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages
(D6600 Only)
Table 122:
Explanation of Automation Output Items (within Message Body only)
Character
Meaning
aaa
Radio account number (in hex), range: 001 to 9C4.
i
Input number, range: 1 to 8.
z
Zone number, range: 1 to 8.
u
User number, range: 1 to 8.
aaaa
Control panel account number.
e
ee
Event code.
eee
eeee
eeeeeeee
Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only).
t
Type code.
z
zz
zzz
Zone (or contact) code.
zzzz
zzzzzz
gg
Group number.
ff
Function code.
aa
Area code.
Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message)
q
(Ademco Contact ID only).
ccc
Hex contact or user code.
Table 123:
Explanation of Printer Output Items
Character
Meaning
dd/dd
Month and day (MM/DD).
tt:tt
Time of message receipt (HH:MM).
S
SafeCom
xx
Line card number, range: 01 to 08.
n
Radio channel number, range: 1 to 8.
aaa
Radio account number (in hex), range: 001 to 9C4.
>
If exists, the signal is in high priority.
e
Error code (for dialer error signals only), range: 0 to 6.
i
Input number, range: 1 to 8.
z
Zone number, range: 1 to 8.
u
User number, range: 1 to 8.
(aaaa)
Control panel account number.