Sony DVCAM DSR-PDX10 Service Manual page 243

Hide thumbs Also See for DVCAM DSR-PDX10:
Table of Contents

Advertisement

DSR-PDX10/PDX10P
3-6.
XLR ADAPTER ADJUSTMENT
Connected athe XLR adapter with the main unit, and perform the
adjustments.
Don't insert any plug in the MIC jack of the main unit.
[Connection of Audio System Measuring Devices]
Connect the audio system measuring devices as shown in Fig. 6-3-
11.
Switch setting of the XLR adapter
INPUT1 REC CH1 SELECT .......................................... CH1
INPUT1 LEVEL ............................................................ LINE
INPUT1 +48V .................................................................. OFF
INPUT2 LEVEL ............................................................ LINE
INPUT2 +48 .................................................................... OFF
Audio oscillator
1. Audio Level Check
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
Checking Method:
1) Input the 1kHz, -4Bs signal in the XLR jack.
2) Check that the 1kHz signal level is the specified value.
Note: The signal-input method shown in the above figure is a simplified
method. Therefore a little waveform distortion occurs in the output
signal. But, there is no hindrance in the audio level check.
600 Ω
Attenuator
600 Ω = 270 Ω (1-249-410-11) + 330 Ω (1-249-411-11)
Main unit
Video (Yellow)
Left (White)
47k Ω
AUDIO/
Right
VIDEO
(Red)
47k Ω
47k Ω (1-249-437-11)
Camera
1kHz, +4dBs signal: XLR jack
INPUT1 and INPUT2
Left or right terminal of
AUDIO/VIDEO jack of the main unit
Audio lebel meter
-10 ± 2dBs
Menu setting of the main unit
XLR SET:
CH1 LEVEL ................................................................ AUTO
CH2 LEVEL ................................................................ AUTO
XLR adapter
INPUT2
TV monitor
Audio level meter
or Distortion meter
Fig. 6-3-11.
6-88
INPUT1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvcam dsr-pdx10pDvcam rmt-811

Table of Contents