Sony DVCAM DSR-PDX10 Service Manual page 181

Hide thumbs Also See for DVCAM DSR-PDX10:
Table of Contents

Advertisement

DSR-PDX10/PDX10P
6. Flange Back Check
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Switch setting:
POWER ......................................................................... CAMERA
Note2: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Checking method:
1) Select page: 6, address: 40, and set data: 01.
2) Select page: 6, address: 41, and set data: 01.
3) Place the Siemens star 2.0m from the front of the lens.
4) To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5) Shoot the Siemens star with the zoom TELE end.
6) Turn on the auto focus.
7) Check that the lens is focused (Note2).
8) Select page: 6, address: 21, and set data: 10.
9) Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1) Select page: 6, address: 21, and set data: 00.
2) Select page: 6, address: 40, and set data: 00.
3) Select page: 6, address: 41, and set data: 00.
4) Select page: 0, address: 03, and set data: 00.
Siemens star (2.0m from the front of
the lens) (Luminance : 350 ± 50 lux)
Check operation on TV monitor
Focused at the TELE end and WIDE end.
Odd: Focused
Even: Unfocused
7. Picture Frame Setting
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The following adjustments should be carried out upon completion
of "Flange Back Adjustment".
Note2: The data of page: 0, address: 10 must be "00".
Switch setting:
1) POWER .................................................................. CAMERA
2) DIGITAL ZOOM (Menu display) ................................... OFF
3) STEADY SHOT (Menu display) ..................................... OFF
4) FOCUS .................................................................. MANUAL
Setting method:
1) Adjust the zoom and the camera direction, and set to the
specified position.
2) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using "Color reproduction adjustment frame".
Check on the oscilloscope
1. Horizontal period
A=B
B
A
2. Vertical period
E
Check on the monitor TV (Underscanned mode)
Color bar chart picture frame
6-26
Color bar chart (Color reproduction
adjustment frame) (1.0m from the front
of the lens)
Video terminal of AUDIO/VIDEO jack
Oscilloscope and TV monitor
A=B, C=D, E=F
C=D
C
D
Fig. 6-1-12.
E=F
F
V
Fig. 6-1-13.
Monitor TV picture frame
Fig. 6-1-14.