Siemens SINUMERIK 840DE sl Commissioning Manual page 668

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Technologies and cycles
21.11 Compare cycles version
4. Enter the planned version for the cycles files in the <info> tag with "defaultFileVersion" and
the details for the complete version in the <Version> tag.
5. Close the file to save the changes.
Example:
<info defaultFileType=" *.spf *.cpf" defaultFileVersion="05.05.00.00"
linkname="CMA" linkpath="//NC/CMA.DIR" EffDirOrder="CUS CMA">
<Name>Manufacturer cycles</Name>
<Version>5.5.0.0</Version>
<Link>
<Name>CUS</Name>
<Path>//NC/CUS.DIR</Path>
</Link>
</info>
Adapting the version path file
If the version file is saved in the standard directory, and a current oem\versions.xml is available,
no changes are required. In all other cases, the path data can be manually changed:
1. Open the versions.xml file under /oem
2. Replace the standard path in the <Path> tag for the "Manufacturers Cycles" with your own
path for the version file.
3. Close the file to save the changes.
Standard:
<Component>
<Name>Manufacturer Cycles</Name>
<Path>/siemens/sinumerik/hmi/data/version/oem/cma</Path>
</Component>
Example:
<Component>
<Name>Manufacturer Cycles</Name>
<Path>/oem/sinumerik/hmi/data/version/oem/cma</Path>
</Component>
654
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
SINUMERIK Operate (IM9)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents