Siemens SINUMERIK 840Di sl Function Manual page 54

Eps network services
Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

2 Maschine information
2.3 Test series on the machine
Fig. 2-30: Saving the prolog/epilog program permanently
Call sequence of the NC programs
The prolog and epilog program is executed before and after each measurement
movement. The program is also called at the start of a test series and at the end of
a test series.
Example of a call sequence:
Prolog for test series (testType == "FRAME")
Prolog for measurement series1 (testType == "CIRCULARITY")
Checking the return parameters
Measurement1
Epilog for measurement series1 (testType == "CIRCULARITY")
Prolog for measurement series2 (testType == "EQUABILITY")
Checking the return parameters
Measurement2
Epilog for measurement series2 (testType == "EQUABILITY")
Prolog for measurement series3 (testType == "UNIVERSAL")
Checking the return parameters
Measurement3
Epilog for measurement series3 (testType == "UNIVERSAL")
2-54
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 12/2008
12/2008

Advertisement

Table of Contents
loading