Siemens Sinumerik 840D Series Function Manual page 230

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

7 Peripherals/Accessories
7.3 Pressure sensor
Characteristics
Accessories
7-230
Table 7-4
Characteristics of pressure sensors
Characteristic
Signal voltage
Supply voltage
0811 405 540
0811 405 547
0811 405 5554
0811 405 531
0811 405 532
"Dynamic" overload capability
"Static" overload capability
Burst pressure
Linearity deviation with hysteresis
Zero point scatter
Sensitivity scatter
Temperature coefficient of zero point
Temperature coefficient of sensitivity
Measurement temperature range (compen-
sated)
Operating temperature range
Storage temperature range
Hydraulic dead volume
Measuring frequency (-3 dB)
Natural frequency
Max. acceleration
Connecting piece material (hydraulic)
Membrane material
Hydraulic connection
A 4-pin square connector is supplied with the following pressure sensors with
order nos.:
0811 405 540
0811 405 547
0811 405 554.
For replacement purposes, it can be ordered under order no.: 1 834 484 061 or
1 834 484 063 from Bosch Rexroth AG.
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Value range
0...10 V
13...28 V DC
13...28 V DC
13...28 V DC
12...28 V DC
12...28 V DC
6
2 x p
(up to 20 x 10
load cycle)
nom
3 x p
(up to 10 x 0.5 sec each)
nom
>1500 bar
<"0.5%
<"0.5%
<"0.5%
<"0.2%/10 °C
<"0.25%/10 °C
+10 to +70 °C
-10 to +80°C
-30 to +90°C
3
Approx. 0.5 cm
[1 kHz
w10 kHz
[25 g (g=9.81 ms
2
)
X 5 Cr Ni 18 10
X 5 Cr Ni Cu Nb 17 4
G 1/4 (ISO 228)
 Siemens AG, 2003. All rights reserved
10.03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digitalSinumerik 840dieSinumerik 840dSinumerik 840deSinumerik 840di

Table of Contents