6 Hydraulics Diagnostics
310 775
Explanation
Response
Remedy
Continue program
311 710
Explanation
Response
Remedy
Continue program
6-216
Axis %1, drive %2 overlap between breakpoint range and saturation re-
gion of valve characteristic
%1 = NC axis number
%2 = drive number
The breakpoint range and saturation region of the valve characteristic are over-
lapping.
NC not ready.
Under certain circumstances it can be switched over across the entire channel
via MD.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
The NC switches to follow-up mode.
Alarm display.
Interface signals are set.
The breakpoint range and saturation region overlap if:
S
positive quadrant:
(MD 5465+MD 5466)>MD 5486
S
negative quadrant: (MD 5468+MD 5466)>MD 5488
Enter a valid combination in the above drive MD.
Cancel alarm on all channels by pressing RESET. Restart part program.
Axis %1, drive %2 resolution invalid for SSI motor measuring system
%1 = NC axis number
%2 = drive number
The motor measuring system is incorrectly configured for an SSI encoder:
MD 5022 ENC_ABS_RESOL_MOTOR must not be zero.
NC not ready.
Channel not ready.
NC stopped in response to alarm.
NC start disable.
Alarm display.
Interface signals are set.
Set MD 5022 to the correct value
Rotary encoder: Single-turn resolution (increments per revolution)
Linear encoder: Resolution of one increment (in nanometers)
Switch control system OFF and ON again.
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Siemens AG, 2003. All rights reserved
10.03