Manipulated Voltage Limitation - Siemens Sinumerik 840D Series Function Manual

Hla module
Hide thumbs Also See for Sinumerik 840D Series:
Table of Contents

Advertisement

4 Firmware Drive Functions
4.5 Manipulated voltage output
4.5.3

Manipulated voltage limitation

5474
OUTPUT_VOLTAGE_POS_LIMIT [n]
Manipulated voltage limitation positive
Unit:
Default:
V
10.0
5475
OUTPUT_VOLTAGE_NEG_LIMIT [n]
Manipulated voltage limitation negative
Unit:
Default:
V
10.0
Output value
inversion
5476
OUTPUT_VOLTAGE_INVERSION
Manipulated variable inversion
Bit 0= 0: No inversion
1: Inversion
Unit:
Default:
-
0
4-132
0...7 index of the parameter set
Minimum:
Maximum:
1.0
10.0
The manipulated variable setpoint is limited in the positive direction to the value
set in MD 5474 before the D/A conversion. A message is sent to the PLC if the
limit is violated.
0...7 index of the parameter set
Minimum:
Maximum:
1.0
10.0
The manipulated variable setpoint is limited in the negative direction to the value
set in MD 5475 before the D/A conversion. A message is sent to the PLC if the
limit is violated.
Minimum:
Maximum:
0
1
The voltage output (manipulated variable) can be inverted in machine data MD
5476 in order to compensate for differences in sign in the piping or wiring. Alter-
natively, the wiring of the manipulated variable for the valve could be altered.
Definition of direction: See Subsection 3.9.1.
SINUMERIK 840D/SIMODRIVE 611 digital, HLA Module (FBHLA) - 10.03 Edition
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
FLOAT
Immediately
Cross reference: -
Related to:
Protection level:
HLA
3/3
Data type:
Active:
UNS.WORD
Immediately
 Siemens AG, 2003. All rights reserved