Table 4-11
Technical data for Single Motor Modules booksize (45 to 200 A)
Internal air cooling
Rated current
Voltage
Infeed:
DC link voltage
Electronics power supply
Output voltage
Overvoltage trip threshold
Undervoltage trip threshold
Electronics current
consumption at 24 V
Total power loss
(including electronic losses)
Rated output current (l
)
n
Base load current (I
)
geund
Intermittent duty current (l
40 %
Peak current (l
)
max
DC link busbar current
carrying capacity
24 V busbar current carrying
capacity
Rated power
(with DC link voltage of
600 V
and clock cycle
DC
frequency of 4 kHz)
Max. pulse frequency
without derating
Max. pulse frequency with
derating
Max. ambient temperature
without derating
Max. ambient temperature
with derating
DC link capacitance
Sound pressure level
Cooling method (with fan)
Cooling air requirement
Weight
1 For an overview, see the power loss tables in Chapter Cabinet design
Booksize Power Units
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5
6SL3120–
1TE24-5AAx
A
45
V
510 – 720
DC
V
24 (20.4 - 28.8)
DC
V
0 - 0.67 x DC link voltage
ACrms
V
820 ± 2 %
DC
V
380 ± 2 %
DC
A
1.2
DC
W
458.8
1
A
45
ACrms
A
38
)
A
60
s6
ACrms
A
85
ACrms
A
200
DC
A
20
DC
kW
24
kHz
4
kHz
16
°C
40
°C
55
μF
1175
dB(A)
<65
Internal fan
m
/h
112
3
kg
9
4.2 Motor Modules with internal air cooling
1TE26-0AAx
1TE28-5AAx
60
85
1.2
1.5
618.8
786
60
85
51
68
80
110
113
141
200
200
20
20
32
46
4
4
16
16
40
40
55
55
1410
1880
<65
<60
Internal fan
Internal fan
112
160
9
15
Motor Modules Booksize
1TE31-3AAx
1TE32-0AAx
132
200
1.5
1.5
1286
2086
132
200
105
141
150
230
210
282
200
200
20
20
71
107
4
4
16
16
40
40
55
55
2820
3995
<73
<73
Mounted fan
Mounted fan
520
520
21
21
293