Figure 3-78
Table 3-58
Dimensions of the installation openings for the Power Module with external air cooling
Module width
50 mm
100 mm
150 mm
200 mm
300 mm
Booksize Power Units
Equipment Manual, (GH2), 07/2007, 6SL3097-2AC00-0BP5
3.7 Smart Line Modules (5 kW und 10 kW) with external air cooling
Installation openings for the Power Module with external air cooling (50 mm to 200 mm)
W [mm] (inches)
41.5 + 0.3 (1.63 + 0.012)
89.5 + 0.3 (3.52 + 0.012)
133 + 0.3 (5.24 + 0.012)
173 + 0.3 (6.81 + 0.012)
278 + 0.3 (10.94 + 0.012)
w1 [mm] (inches)
20.75 +0.15 (0.82 +0.006)
19.75 +0.15 (0.78 + 0.006)
16.5 +0.15 (0.65 + 0.006)
11.5 +0.15 (0.45 + 0.006)
14.0 ± 0.15 (0.55 ± 0.006)
Line Modules Booksize
w2 [mm] (inches)
0
50 ± 0.15 (1.97 ± 0.006)
100 ± 0.15 (3.94 ± 0.006)
150 ± 0.15 (5.91 ± 0.006)
250 + 0.15 (9.84 + 0.006)
263