05.07
Missing files
Fig. 4-23: Consistency Check dialog: Missing files
This dialog displays administrative data records for which the corresponding file is
missing.
The complete path in which the file should appear is displayed. This path
comprises the NC data master directory (in this case:
C:\Siemens\MCIS\Data\DNC\Data\) and the subdirectories for the group(s),
machine, workpiece and attachments for NC data. The file name of an NC
administrative data record comprises the NC data name, the version number and
the NC data type.
Example: data name_13.MPF
To delete the selected administrative data records from the database, choose
Delete.
You can also use Microsoft Explorer to add the file at the required location. The
name of the file is not case sensitive. If you carry out this step, you have to close
the Consistency Check dialog and open it again so that this inconsistency is no
longer displayed.
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
DNC Plant/DNC Cell (FBDN1)
4 NC data management
FBDN1/4-109