Block %2 No Geometry Axis Programmed; Block %2 Spindle %3 Selected Gear Stage %4 Not Installed; Block %2 Spindle %3 Inserted Gear Stage %4 For Tapping Not Installed - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16740
[Channel %1: ] Block %2 no geometry axis programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No geometry axis was programmed for tapping (G33) or for rigid tapping (G331, G332). The geometry axis is, how-
ever, essential if an interpolation parameter has been specified.
Example:
N100 G33 Z400 K2 ; thread pitch 2mm, thread end Z=400 mm
N200 SPOS=0 ; position spindle in axis mode
N201 G90 G331 Z-50 K-2 ; tapping to Z=-50, counterclockwise
N202 G332 Z5 ; retraction, direction reversal automatic
N203 S500 M03 ; spindle again in spindle mode
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Specify geometry axis and corresponding interpolation parameters.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16746
[Channel %1: ] Block %2 spindle %3 selected gear stage %4 not installed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
%4 = Gear stage
Definitions:
The first gear stage data block is active. The required gear stage is not installed in the 1st gear stage data block. The
number of gear stages installed is configured in MD35090 $MA_NUM_GEAR_STEPS.
Examples of the occurrence of the alarm with 3 three gear stages installed (MD 35090 $MA_NUM_GEAR_STEPS =
3):
* ... M44 or M45 has been programmed for the spindle concerned
*...M70 has been programmed and MD35014 $MA_GEAR_STEP_USED_IN_AXISMODE is larger than 3.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program: Only those valid gear stages can be entered which have also been installed according to
MD35090 $MA_NUM_GEAR_STEPS.
Limit M70 configuration (MD 35014 $MA_GEAR_STEP_USED_IN_AXISMODE) to MD35090
$MA_NUM_GEAR_STEPS.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16747
[Channel %1: ] Block %2 spindle %3 inserted gear stage %4 for tapping not installed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
%4 = Gear stage
Definitions:
The second gear stage data block has been activated for tapping with G331.
However, the current gear stage has not been installed in the second gear stage data block. The number of gear
stages installed is configured in MD35092 $MA_NUM_GEAR_STEPS2. The gear stage cannot be changed in travers-
ing blocks. The gear stage appropriate for the speed must be loaded before the traversing block.