CHAPTER 3. Connecting Cables

3.5.2 Cable Connection of RET

Below is the method for connecting the Remote Electrical Tilting (RET) cable to control
the antenna tilting angle remotely.
RET
- When applying 27 VDC voltage, a current of 1 A or less must be supplied to the
- For the external material of the RET, metal without vent hole or the UL certificated
1
(Samwoo, SU-20SP-8P)
2
3-20
RET from the RRH-2WB.
material must be use.
RET Connector
RET Cable
Figure 3.10 Cable Connection of RET
Heat Shrink Tube
(Jelly Type, Black)