Samsung RRH-2WB Installation Manual page 23

Mobile wimax/td-lte
Table of Contents

Advertisement

Environmental Condition
The table below lists the environmental conditions and related standards such as
operational temperature and humidity.
Category
Temperature Condition
Humidity Condition
Altitude
Vibration
Noise (sound pressure level)
Electromagnetic Wave (EMI)
RF Regulation
a) The standards of temperature/humidity conditions are based on the value on the position where is 400 mm
(1.3 ft) away from the front of the DU and in the height of 1.5 m (5 ft) on the bottom.
RF Specification
The table below lists the RF characteristics of the RRH-2WB.
Category
Total Tx Output Power
Tx Constellation error
RX Sensitivity
© SAMSUNG Electronics Co., Ltd.
Mobile WiMAX/TD-LTE RRH-2WB Installation Manual/Ver.2.0
a)
-40~+50°C (-104~122°F)
a)
5~100%, condensing, not to exceed 30g/m
-60~1,800 m (197~6,000 ft)
GR-487-CORE Sec.3.39
- Transportation shock
- Transportation vibration
- Installation shock
- Environmentally induced vibration
- Earthquake resistance
Under 65 dBA in height of 1.0 m (3 ft) and distance of 1.5 m (5 ft).
FCC Title 47 Part 15 Class B
EN 301 489 Section 7.1 EMC emission
GR-1089-CORE(Issue4) Sec. 3.2 Emission Criteria
FCC Title 47 Part 27
40 W
- Mobile WiMAX: 5 + 5 W
- TD-LTE: 10 + 10 + 10 + 10 W
- Mobile WiMAX: RCT
- TD-LTE: 3 GPP TS 36.104
- Mobile WiMAX: RCT
- TD-LTE: 3 GPP TS 36.104
Range
3
absolute humidity
Description
1-5

Advertisement

Table of Contents
loading

Table of Contents