Connection

5.4 Signaling contact

5.4
Signaling contact
Information on the signaling contact
● The signaling contact is a floating switch with which you can output the mode.
The signaling contact must be operated within the range of the operating voltage.
When the bypass relay is in bypass mode, it closes the signaling contact. If the bypass
relay is in normal mode, the signaling contact is open.
● The signaling contact is connected using a 2-pin plug-in terminal block (spring-loaded
terminal). The terminal block ships with the device.
● To wire up the signaling contact, use a copper cable of category 18-12 AWG or a cable
with a cross-section of 0.75 to 2.5 mm
NOTICE
Damage due to voltage being too high
The signaling contact can be subjected to a maximum load of 100 mA (safety extra low
voltage SELV 12 VDC / 24 VDC / 48 VDC).
Position and assignment
Figure 5-2
Pin number
Pin 1
Pin 2
40
Position of the signaling contact on the SCALANCE XC100-4OBR and the assignment of
the terminal block
Assignment
F1
F2
.
2
Operating Instructions, 10/2013, C79000-G8976-C297-02
SCALANCE XC100-4OBR