Description of the device

3.2 Purpose

3.2
Purpose
Basic function
With the optical bypass relay SCALANCE XC100-4OBR, you can activate and deactivate
end devices in bus, star and ring structures without interrupting the communication between
other network components.
If an error occurs, the bypass relay bypasses the connected end device so that the
connection in the network is retained.
An end device is a device connected to the network via a bypass relay.
Normal operation
When the SCALANCE XC100-4OBR is supplied with power, the network interfaces are
connected to the end device interfaces of the bypass relay
bypass relay is connected is therefore in the network.
14
. The end device to which the
Operating Instructions, 10/2013, C79000-G8976-C297-02