Diagnosing transceiver modules

The device provides the alarm and digital diagnosis features for transceiver modules. When a transceiver
module fails or is not operating correctly, you can perform the following tasks:
Check the alarms that exist on the transceiver module to identify the fault source.
Examine the key parameters monitored by the digital diagnosis feature, including the temperature,
voltage, laser bias current, TX power, and RX power.
To diagnose transceiver modules, execute the following commands in any view:
Task
Display transceiver alarms.
Display the current values of the
digital diagnosis parameters on
transceiver modules.

Disabling alarm traps for transceiver modules

Disable alarm traps if the transceiver modules were manufactured or sold by HP.
The device regularly detects transceiver modules that have a vendor name other than HP or do not have
a vendor name. Upon detecting such a transceiver module, the device repeatedly outputs traps and logs
to notify the user to replace the module.
To disable alarm traps for transceiver modules:
Step
1.
Enter system view.
2.
Disable alarm traps for
transceiver modules.

Restoring the factory-default configuration

CAUTION:
This task is disruptive. Use this task only when you cannot troubleshoot the device by using other methods,
or you want to use the device in a different scenario.
This feature performs the following tasks:
Deletes all configuration files (.cfg files) in the root directories of the storage media.
Deletes all log files (.log files in the folder /logfile).
Clears all log information (in the log buffer), trap information, and debugging information.
Restores the parameters for the BootWare to the factory-default settings.
Command
display transceiver alarm
{ interface [ interface-type
interface-number ] }
display transceiver diagnosis
{ interface [ interface-type
interface-number ] }
Command
system-view
transceiver phony-alarm-disable
237
Remarks
N/A
This command cannot display
information about some
transceiver modules.
Remarks
N/A
By default, alarm traps are
enabled for transceiver modules.