Siemens SIMATIC S5 Manual page 225

Positioning module 1p 247 for stepper motors
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Standard Function Block FB165
BA
:
D, KYx,y
Specification of the mode to be executed, selection binary/BCD conversion.
Job number
20
21
22
23
24
64
65
66
67
68
69
70
If you attempt to send a mode via an illegal axis (data channel), the I P247 sends a negative ac-
knowledgement (see FB 164).
* Can only be read out via the data channel, when all DB numbers are different.
D, KYx,y
:
Specification of the source data block. For the programmable controllers S5-1 15U andS5-150U
it
not possible to program data block type DX.
is
6-32
x
no binary/BCD conversion
x
> < 0 :
and distance to go.
Evaluation only in mode BA 66.
y = Operating mode (job
20<
y <24
70 read jobs
Operating mode
input machine data
delete machine data
input machining program
delete machining program
input SYSID
read machine data directory
read machining program directory all axes + data channel
read actual values
read machine data
read machine data overview
read machining program
read SYSID
x = data block type
x
= O : data block type DB
=
Y
source data block number
In modes 20, 22 and 24 (write jobs) the specified data block
(source DB) is in the PC memory.
O <= y c= 255
In modes 67 and 69 (read jobs) the specified data block
(source DB) is in the RAM of the positioning module.
number)
write and delete jobs
Possible on
one axis
one axis
data channel
data channel
data channel
all axes + data channel
one axis
one axis + data channel*
all axes + data channel
all axes + data channel
all axes + data channel

Advertisement

Table of Contents
loading