Fig, 4/1 1 Traversing in the incremental absolute mode
4.2.7

Incremental Approach Relative (Mode 7)

In this mode, a preset distance forwards or backwards is travel led from the current actual posi-
tion. The same conditions apply to the speed as for mode 6 "incremental approach absolute".
This mode can also be executed when the reference point is deleted. The travel direction is deter-
mined by the operating instruction "forward" or "reverse".
Forward 200mm
v T
II
0
-
I
Fig. 4/1 2 Traversing in the "incremental approach relative" mode
With a linear axis, the distance to be travelled must be such that the resulting target position with
a reference point set remains within the traversing range between the two software limit switches
(also taking into account zero point offsets). If this is not the case, the job is aborted and the
error "traversing range exceeded" is displayed. With a rotary axis, the distance travel led is limited
to +/-200 m (+/-20 000 inches, +/-200 000 degrees). If this limit is not adhered to, the job is
also aborted and the error message "illegal dist. spec. " is generated.
4 - 1 6
mm
200
–––
mm
t: Time
v: Speed
O: Speed in machine data
d = 200mm
d: Distance
t: Time
v: Speed
O: Speed in machine data
\
\
\
\
\
\
\
stop
(abort)