6
To select for each bus whether the GPI link setting is
enabled or disabled, select the bus to which the setting
applies.
7
In the <Bus> group, select any of the following.
Enable: Enables the GPI link setting for the selected
bus.
Disable: Disables the GPI link setting for the selected
bus.
All Enable: Enables the GPI link setting for all buses.
Setting the delay value
1
In the Engineering Setup >Switcher >Link >GPI Link
>GPI Link Adjust menu (7336.5), select the output
port for which you want to set the delay value, and the
corresponding delay value.
No.
Parameter
Adjustment
1
GPI Port
GPI output port to be configured
5
Delay
Delay value for the output port
2
Press [Delay Set].
Setting the operation mode when selecting
M/E reentry inputs
When you select a reentry signal in the cross-point control
block of an M/E block (upstream M/E block), the output of
the upstream M/E block is read in. You can set the system
so that when a GPI link is set for the cross-point selected
1)
on the A bus
of the upstream M/E block this triggers the
GPI output.
In the Engineering Setup >Switcher >Link >GPI Link
menu (7336.4), set [Re-Entry Enable] to On or Off.
When set to On, the GPI is executed upstream.
1) When the bus toggle is set to Off, the applicable bus depends on the
position of the fader lever.
Notes
• For reentry, "upstream" applies to a single stage only.
• This setting is common to all GPI output ports.
• GPI output execution on the upstream M/E block is only
possible on buses for which the GPI link is set to
[Enable] in the GPI Link Adjust menu.
• GPI outputs are executed when reentry signals are
selected under the following conditions.
- When selected using buttons in cross-point control
block
- When selected by macro execution
- When selected on the AUX bus remote panel

Setting Links between M/E Banks

The operations for which you can link two M/E banks are
as follows.
• Transition execution (auto transition, cut, and fader lever
operation)
• Next transition selection
• Transition type selection
1
In the Engineering Setup >Switcher >Link >M/E Link
menu (7336.6), specify the link number to set.
2
In the <M/E Select> group, select [Master M/E] (link
3
Select the M/E or PGM/PST link source, then press
[M/E Set].
4
In the <M/E Select> group, select [Linked M/E] (link
destination).
5
Select the M/E or PGM/PST bank you want to be the
link destination, then press [M/E Set].
To link the banks not only for transition execution
but also for the other operations
Press [Transition Only], turning it off.
To release a link
Use the same operation as in step 1 to select the link
number for which you want to release the link setting, then
press [Clear].
Making a Link Setting for Key
Transition
The operations for which you can link two banks are the
following independent key transition operations.
• Auto transition
• Turning the key on or off
1
In the Engineering Setup >Switcher >Link >Key
Transition Link menu (7336.7), specify the link
number to set.
2
In the <Key Select> group, select [Master Key] (link
source).
3
Select the key you want to be the link source, then
press [Key Set].
4
In the <Key Select> group, select [Linked Key] (link
destination).
Settings Relating to Function Links