Reset And Initialization - Sony MVS-6520 User Manual

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

Saving User-Defined Settings
1
Open the Engineering Setup >System >Start Up menu
(7314).
2
Select the target device, and then select one of the
following.
• To save the Setup settings, press [Setup Define].
• To save the Initial Status settings, press [Init Status
Define].
For details about the settings which will be saved,
1 "Data Saved by [Setup Define] and [Initial Status
Define]" (p.
431).
3
Check the message, then press [Yes].
Setting Automatic Loading of
Register Data at Power On (Autoload
Function)
To have specified data read in at power on, press [Power
On File Load] in the Engineering Setup >System >Start Up
menu (7314), turning it on.
This enables the autoload function.
When the autoload function is enabled, a directory
"PWON_LD" appears in the corresponding File menu.
For details about saving data which can be loaded by the
1 "Saving data recalled by autoload"
autoload function,
(p.
304).

Reset and Initialization

You can carry out a reset or memory initialization for a
device.
• Reset: Resets state after powering on.
• All Clear: Clears the memory and restores the factory
default settings. The Network Config, Format, and Start
Up setup values are set by reference to data stored in
non-volatile memory, and the system automatically
starts up. It is not necessary to reset the Date/Time
settings.
1 "Saving and Recalling Setup Data"
For details,
(p.
316).
Notes
• Resetting SWR1 also resets DME1 at the same time.
• Resetting SWR1 also resets PNL1 at the same time.
However, resetting PNL1 does not reset SWR1.
1
In the status area of the Engineering Setup >System
>Initialize menu (7315), select the device.
2
In the <Initialize> group, select one of the following
modes.
All Clear: Initializes the target device, causing it to
restart in the factory default state.
3
Press [Execute].
4
Check the message, then press [Yes].
Setting the Control Panel
Type
You use this procedure to set the type of ICP-series control
panel connected to the MVS system.
1
In the Engineering Setup >System >Install/Unit
Config menu (7316), select "PNL1" and press [Unit
Config].
The Unit Config menu (7316.8) appears.
2
In the <ICP Type> group, select the type of the control
panel.
You can select [ICP-6530], [ICP-6520], [ICP-3000],
or [ICP-3016].
3
Press [Execute].
4
Check the message, then press [Yes].
Installation and Device
Setup
This installs the software and firmware in all devices
(including the DCU) connected to the LAN.
Notes
The DME1 software is included in the MVS-6520/6530/
3000A software.
Reset and Initialization / Setting the Control Panel Type / Installation and Device Setup
317

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents