Frame Memory And Color Correction - Sony MVS-6520 User Manual

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

Off: Bus fixed mode
1 "Fader Lever Operation in Bus Fixed
For details,
Mode" (p.
73).
Enabling or disabling the fade-to-black
function
In the <FTB> group of the Engineering Setup >Switcher
>Transition menu (7334), press the program output name
to toggle between On and Off.
On: Enables fade-to-black.
Off: Disables fade-to-black.
Notes
The PGM2 to PGM4 settings are valid in Multi Program
mode only.
Setting a preset color mix
1
Open the Engineering Setup >Switcher >Transition
>Preset Color Mix menu (7334.1).
2
In the <Stroke Mode> group, select whether to carry
out a transition in one stroke or two strokes.
Normal: Carries out a preset color mix with two
transition operations.
Single: Carries out a preset color mix with a single
transition operation.
Notes
In bus fixed mode
"Single."
3
In the <Non Drop Key> group, select the key setting
for a transition including a key.
To carry out the transition with the key state
maintained, press [Key1] to [Key4], turning them on.
4
If each time a transition ends the transition type is to
return to the previous setting, press [One Time
Enable].
Settings relating to fader lever operations
To select the way in which the fader lever position and the
transition progress are related, use the following
procedure.
1
Open the Engineering Setup >Switcher >Transition
>Transition Curve menu (7334.2).
2
In the <Fader Curve> group, select the fader lever
operation mode.
356
Settings Relating to Keys, Wipes, Frame Memory and Color Correction
(1 p.
355), the setting is fixed to
Normal: The transition progress is linear, according to
the fader lever position (factory default setting).
Adv Tally Mode: When the fader lever is moved from
the end of its travel, the tally is output slightly
before the transition starts.
Settings Relating to Keys,
Wipes, Frame Memory
and Color Correction
Settings for the Show Key Function
1
Open the Engineering Setup >Switcher >Key/Wipe/
FM/CCR >Show Key menu (7335.1).
2
In the <Show Key Enable> group, press the signal for
which "show key" is enabled, turning it on.
3
To set the time for which "show key" is held, press
[Hold Time].
4
Adjust the following parameter.
No.
Parameter
Adjustment
1
Hold Time
Show key hold time
Settings for Key Auto Drop Function
The "key auto drop" function automatically switches off a
particular key when you press a cross-point button in a bus
that outputs the background on the particular switcher
bank (PGM/PST or M/E-1).
When the background output bus is in flip-flop mode, this
is always the A bus. In bus-fixed mode, it is either the A
bus or the B bus depending on the fader lever position
(1 "Fader Lever Operation in Bus Fixed Mode" (p.
1
In the Engineering Setup >Switcher >Key/Wipe/FM/
CCR menu (7335), press [Key Auto Drop].
The Key Auto Drop menu (7335.2) appears.
73)).