Applicant: Motorola Solutions
268 | Site Controller
LED
LED/Port Name
LED4
BTS Alarm
LED5
LED6
LED7
LED8
Send Feedback
| September 2014 | 6802800U74-AD
Position
Front Panel
Port 1 LED1
BR1
Port 1 LED2
Port 2 LED1
BR2
Port 2 LED2
Equipment Type: ABZ89FC5827 / 109AB-5827
Controlled by
•
RED Blinking: Calibration is re-
quired.
•
GREEN/RED Blinking: Frequency
lock is required, pull in.
Forced Non-Synchronized Configura-
tion (FNC) Mode:
•
OFF: Application is not running, free
run or NTP.
•
GREEN: BTS synchronized to GPS.
•
GREEN/AMBER Blinking: BTS
synchronized to a standby SC.
•
AMBER Blinking: In training.
•
RED Blinking: Calibration is re-
quired.
•
GREEN/RED Blinking: Frequency
lock is required, pull in.
SW
•
OFF: No alarms.
•
GREEN: Not used.
•
AMBER: CAN Bus problems, Exter-
nal alarms (minor Alarm)
•
RED: Major/critical alarm, for details
see
Table 92: Site Controller LED
Fault Indications on page 311
SW
3 LEDs blinking together: R (red) RRR-
>Y (yellow) YYY->G (green) GGG –
LED test just after BTS reset or power
up
SW
RRRR blinking – replace the FRU
SW
RRR blinking – replace the FRU
SW
R->RR->RRR->RRRR->R->RR->RRR-
>RRRR-> ... – initializing file system
(do not turn off and wait a few minutes,
then application and configuration will
have to be downloaded after initializa-
tion).
HW, Enet switch
•
OFF: Ethernet link not present.
•
GREEN: Ethernet link present.
HW, Enet switch
•
OFF: Ethernet activity not present.
•
YELLOW: Ethernet activity present.
HW, Enet switch
•
OFF: Ethernet link not present.
•
GREEN: Ethernet link present.
HW, Enet switch
•
OFF: Ethernet activity not present.
Indication
Table continued...
Exhibit D2