Table 92: Site Controller Led Fault Indications - Motorola DIMETRA MTS 4 Installation, Configuration, And Service Manual

Dimetra ip scalable (dips); dimetra ip compact (dipc)/scalable dimetra ip (sdip); dimetra ip micro/dimetra ip lite
Table of Contents

Advertisement

Applicant: Motorola Solutions
268 | Site Controller
LED
LED/Port Name
LED4
BTS Alarm
LED5
LED6
LED7
LED8
Send Feedback
| September 2014 | 6802800U74-AD
Position
Front Panel
Port 1 LED1
BR1
Port 1 LED2
Port 2 LED1
BR2
Port 2 LED2
Equipment Type: ABZ89FC5827 / 109AB-5827
Controlled by
RED Blinking: Calibration is re-
quired.
GREEN/RED Blinking: Frequency
lock is required, pull in.
Forced Non-Synchronized Configura-
tion (FNC) Mode:
OFF: Application is not running, free
run or NTP.
GREEN: BTS synchronized to GPS.
GREEN/AMBER Blinking: BTS
synchronized to a standby SC.
AMBER Blinking: In training.
RED Blinking: Calibration is re-
quired.
GREEN/RED Blinking: Frequency
lock is required, pull in.
SW
OFF: No alarms.
GREEN: Not used.
AMBER: CAN Bus problems, Exter-
nal alarms (minor Alarm)
RED: Major/critical alarm, for details
see
Table 92: Site Controller LED
Fault Indications on page 311
SW
3 LEDs blinking together: R (red) RRR-
>Y (yellow) YYY->G (green) GGG –
LED test just after BTS reset or power
up
SW
RRRR blinking – replace the FRU
SW
RRR blinking – replace the FRU
SW
R->RR->RRR->RRRR->R->RR->RRR-
>RRRR-> ... – initializing file system
(do not turn off and wait a few minutes,
then application and configuration will
have to be downloaded after initializa-
tion).
HW, Enet switch
OFF: Ethernet link not present.
GREEN: Ethernet link present.
HW, Enet switch
OFF: Ethernet activity not present.
YELLOW: Ethernet activity present.
HW, Enet switch
OFF: Ethernet link not present.
GREEN: Ethernet link present.
HW, Enet switch
OFF: Ethernet activity not present.
Indication
Table continued...