400 | Expansion Options
Figure 204: M3 Screw position
6 Remove the Ribbon cable from the Module cage.
7 Mount the two brackets to the Module cage using 10 pcs. M4 screws.
8 Bend in the area at the back of the Module Cages for Ribbon cables to be routed through later.
Assembling the Module Cage in the MTS 4 Cabinet
Procedure:
1 Remove the Module Cage Beauty Plate (if any).
2 Mount all cables going from the lower Module Cage in your specific configuration and fix them temporarily in the
rack before mounting the air separator shelf and module cage.
•
Ethernet cables from Base Radio(s) in lower Module Cage to SC in upper Module Cage (SC2).
•
Ethernet cables from Base Radio(s) in upper Module Cage to SC in lower Module Cage (SC1).
•
CAN Bus cables to and from Filters.
3 Assemble the Air Separator shelf above the existing Module Cage using four M6 screws.
4 Assemble the Module Cage extracted from MTS 2 in
5 Connect the power supply cables and optional backup battery cables.
6 Connect the Ethernet cables and CAN Bus cables mounted in Step 2 above.
7 Switch ON the Power Supply Unit.
8 Check the LED indicators to verify the PSU is operating correctly.
Send Feedback
| September 2014 | 6802800U74-AD
Note: This would typically be:
Note: For more information regarding assembling of a module cage in the MTS 4 Cabinet, see Adding
Additional Module Cage to MTS 4.