Electrical Installation; Technical Data - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Power Modules
3.1 Power Modules Blocksize (PM340)
3.1.6

Electrical installation

Operation on non-grounded line supply systems (IT)
It is not permissible to use Power Modules with series line filter in IT line supply systems.
In order that the Power Modules remain functional when ground faults occur, a line reactor
must be connected in series.
3.1.7

Technical data

Table 3-9
Technical data PM340, Part 1
Line supply voltage 1-ph. 230 V AC ± 10 %
PM340
PM340 with integrated line filter
Rated output current I
n
Base load current (I
)
H
Output current for S6 duty (40%) l
Max. output current (l
)
max
Rated power based on I
n
Rated pulse frequency
Efficiency η
Power loss
Cooling air requirement
Sound pressure level
24 V DC power supply
for the Control Unit
Rated input current
1)
with line reactor
without line reactor
Resistance value of the external
braking resistor
Max. cable length to braking resistor
Line supply connection
L, N
Motor connection
U2, V2, W2
DC link connection, connection for
braking resistor DCP/R1, DCN, R2
PE connection
3-30
6SL3210–
1SB11-0UA0
6SL3210–
1SB11-0AA0
A
0.9
A
0.8
A
1.4
s6
A
2.0
kW
0.12
kHz
4
0.80
kW
0.06
m
/s
0.005
3
dB(A)
< 45
A
1.0
A
1.9
2.2
Ohm
≥ 180
m
15
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
at the housing
with M 4 screw
1SB12-3UA0
1SB12-3AA0
2.3
2.0
3.3
4.6
0.37
4
0.90
0.075
0.005
< 45
1.0
4.8
6.0
≥ 180
15
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
2
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
2
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
2
at the housing
with M 4 screw
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
1SB14-0UA0
1SB14-0AA0
3.9
3.4
5.5
7.8
0.75
4
0.91
0.11
0.005
< 45
1.0
8
10
≥ 180
15
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
2
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
2
Screw terminals
for cable cross-sections
1.0 to 2.5 mm
2
at the housing
with M 4 screw
Equipment Manual AC Drive