Table 4-8
Technical data, Braking Modules
Order No.
Suitable for installation in Power Modules, frame size
P
power (rated power)
DB
P
power (peak power)
15
P
power
20
P
power
40
Variable response thresholds
Digital input
Rated voltage
Low level (an open digital input is interpreted as "low")
High level
Current drain (typical at 24 V DC)
Max. cross-section that can be connected
Digital output (continued-short-circuit-proof)
Rated voltage
Max. load current of the digital output
Max. cross-section that can be connected
R1/R2 connection
Max. connection cross-section R1/R2
Weight
Equipment Manual AC Drive
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
6SL3300–1AE31-3AA0
FX
25 kW
125 kW
100 kW
50 kW
774 V (673 V)
-3 V to 30 V
-3 V to 5 V
15 V to 30 V
10 mA
1.5 mm² (AWG 14)
24 V DC
500 mA
1.5 mm² (AWG 14)
M8 screw
35 mm²
3.6 kg
DC link components
4.2 Chassis
6SL3300–1AE32-5AA0
GX
50 kW
250 kW
200 kW
100 kW
774 V (673 V)
-3 V to 30 V
-3 V to 5 V
15 V to 30 V
10 mA
1.5 mm² (AWG 14)
24 V DC
500 mA
1.5 mm² (AWG 14)
M8 screw
50 mm²
7.3 kg