Samsung DCS Programming Manual page 361

Combined systems
Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
MMC: 826
FOR:
iDCS500
Purpose: The system clock may be synchronized with an external clock source from a
TEPRI card or may use the internal clock source. In this MMC, you can select to use the
internal clock source or assign the system clock source priority when the external clock
source is used. Options are:
ACTION
1. Open programming and select 826
Display shows
2. Dial priority number 1–9 (e.g. 2)
OR
Press VOLUME keys to select and press RIGHT
soft key
3. Dial cabinet/slot option number 0–9
OR
Press VOLUME keys to select and press RIGHT
soft key
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Related Items:
OS500
PRIORITY 1–3
C1: S1–S9, SELF
C2: S1–S9, SELF
C3: S1–S9, SELF
PRIORITY 1
C1–S1
PRIORITY 2
C1–S2
PRIORITY 3
C1–S3
None
MMC 826 (Page 1 of 1)
MMC PROGRAMS
ASSIGN SYSTEM
CLOCK SOURCE
DISPLAY
REFERENCE CLOCK
PRIORITY 1:C1-S1
REFERENCE CLOCK
PRIORITY 2:C2-S2
REFERENCE CLOCK
PRIORITY 2:C2-S3