(5)
Remove 1 strap, release the harness from
the harness clamp, and take off the exhaust
fan with the duct.
(6)
Release the harness from the harness
clamp, remove the two-sided tape and take
off the exhaust fan.

10.7.17 Temperature/humidity sensor (S3)

(1)
Take off the left cover.
P.2-18 "2.5.3 Left cover"
(2)
Disconnect 1 connector, remove 1 screw,
and then take off the temperature/humidity
sensor.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 10-40
Duct
Fig. 10-41
Temperature/
Humidity sensor
Fig. 10-42