Programming Manual References
None
Feature Guide References
1.11.10 Calling Party Control (CPC) Signal Detection
DTMF Width
Selects the length of the DTMF tone sent to the T1 channel.
Value Range
80 ms, 160 ms
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
CO Pulse Speed
Selects the speed at which pulse dials are sent to the T1 channel.
Value Range
10 pulse/s, 20 pulse/s
Maintenance Console Location
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.5.4.4 Dial Type Selection
Wink Signal Time Out
Specifies the length of time that the PBX waits to receive a wink signal after seizing a trunk. If a wink signal is
not received before this timer expires, the trunk is released.
3.19 [1-1] Slot—Port Property - T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
PC Programming Manual
231