en | Agency Approvals and Requirements
Commercial Burglary, Local
Commercial Burglary, Police Station Connected Protected Premises*
* Systems are approved for Encrypted Line Security when used in conjunction with the
C900V2 Conettix IP Dialer Capture Module and communicating over a packet-switched data
network (PSDN).
Commercial Burglary, Proprietary*
* Systems are approved for Encrypted Line Security when used in conjunction with the
C900V2 Conettix IP Dialer Capture Module and communicating over a packet-switched data
network (PSDN).
2014.09 | 01 | F.01U.306.221
Install at least one IUI-EZ1-NEW Control Center.
Program all zones to use end-of-line supervision.
Install intrusion initiating devices rated to operate over the voltage range of 11.2 VDC to
12.3 VDC.Program all intrusion zones for audible notification.
Do not exceed 60 sec when programming Exit Delay. Refer to Programming Item 126 in
System Programming Items, page 48. Do not exceed 45 sec when programming Entry
Delay. Refer to Programming Item 127 in System Programming Items, page 48. Program
the bell cut-off time for at least of four minutes. Refer to Programming Item 108 in System
Programming Items, page 48.
The system must be able to operate for at least 24 hr, and generate a full alarm output for
at least 4 min without AC power.
Use the D8108A Attack Resistant Enclosure with the D2402 Mounting Skirt.
Install at least one UL Listed 85 dB audible device rated to operate over the voltage range
of 11.2 VDC to 12.3 VDC. All wiring connections between the control panel and device
must be in conduit.
Do not exceed 60 sec when programming Exit Delay. Refer to Programming Item 126 in
System Programming Items, page 48. Do not exceed 60 sec when programming Entry
Delay. Refer to Programming Item 127 in System Programming Items, page 48.
Install a tamper switch to protect the enclosure door.
Set Programming Item 116 to 1 (Daily) to ensure the automatic test report is sent on a
daily basis. Refer to System Programming Items, page 48.
Ensure that the integrated communicator is enabled (Programming Item 304 = 0; refer to
Global Report Routing Items, page 57). Ensure that the system can send low battery
reports (Programming Item 358 = 1, 2, or 3; refer to System Report and Restoral Routing,
page 56).
Install at least one IUI-EZ1-NEW Control Center.
Program the bell cut-off time for at least 15 minutes. Refer to Programming Item 108 in
System Programming Items, page 48.
This system was not evaluated for Bank Safe and Vault applications.
The system must be able to operate for at least 24 hr, and generate a full alarm output for
at least 15 min without AC power.
Refer to Commercial Burglary, Local, page 10 for installation requirements.
Ensure that the integrated communicator is enabled (Programming Item 304 = 0; refer to
Global Report Routing Items, page 57).
The integrated communicator is enabled (Programming Item 304 = 0; refer to Global
Report Routing Items, page 57).
The system has one owner.
The system must be able to operate without AC power for at least 24 hours. The central
station receiver must be able to receive reports without AC power for at least 24 hours.
System Reference Guide
Easy Series Control Panel
Bosch Security Systems, Inc.